Hình minh họa loại thiết bị

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Tham chiếuReference参考

Eaton Tripp Lite PDUMH15HVAT 2.4kW 10-Outlet Local Metered Automatic Transfer Switch PDU 1U Rack-MountEaton Tripp Lite PDUMH15HVAT 2.4kW 10-Outlet Local Metered Automatic Transfer Switch PDU 1U Rack-MountEaton Tripp Lite PDUMH15HVAT 2.4kW 10-Outlet Local Metered Automatic Transfer Switch PDU 1U Rack-Mount

HãngBrand品牌
Eaton
MãSKU型号
PDUMH15HVAT
Cách thứcHow it is supplied供应方式
Không bán lẻ. Mua từ hãng hoặc nhà phân phối được ủy quyền.Not sold here. Buy from the manufacturer or an authorised distributor.不在此零售。向厂家或授权经销商购买。

Xem thông tin gốc trên trang của EatonSee the original information on the Eaton website在 Eaton 官网查看原始信息

Đây là website của hãng, mở ở tab mới. MOTION TECH SYSTEM không bán thiết bị này và không nhận hoa hồng từ đường link.This is the manufacturer’s website and opens in a new tab. MOTION TECH SYSTEM does not sell this device and earns no commission from the link.此为厂家网站,在新标签页打开。MOTION TECH SYSTEM 不销售此设备,也不从此链接获得佣金。

Eaton — Computing Device Accessory. Redundancy: Automatic Transfer Switching in 2-5 ms from primary to secondary power source. Outlets: 10 x C13 outputs; dual IEC-320 C14 inputs; 200-240V single-phaseEaton — Computing Device Accessory. Redundancy: Automatic Transfer Switching in 2-5 ms from primary to secondary power source. Outlets: 10 x C13 outputs; dual IEC-320 C14 inputs; 200-240V single-phaseEaton — Computing Device Accessory. Redundancy: Automatic Transfer Switching in 2-5 ms from primary to secondary power source. Outlets: 10 x C13 outputs; dual IEC-320 C14 inputs; 200-240V single-phase

  • Redundancy: Automatic Transfer Switching in 2-5 ms from primary to secondary power source
  • Outlets: 10 x C13 outputs; dual IEC-320 C14 inputs; 200-240V single-phase
  • Monitoring: Digital ammeter display; LED indicators; optional SNMP/web network management card
  • Redundancy: Automatic Transfer Switching in 2-5 ms from primary to secondary power source
  • Outlets: 10 x C13 outputs; dual IEC-320 C14 inputs; 200-240V single-phase
  • Monitoring: Digital ammeter display; LED indicators; optional SNMP/web network management card
  • Redundancy: Automatic Transfer Switching in 2-5 ms from primary to secondary power source
  • Outlets: 10 x C13 outputs; dual IEC-320 C14 inputs; 200-240V single-phase
  • Monitoring: Digital ammeter display; LED indicators; optional SNMP/web network management card
Gọi tư vấnCall us电话咨询

Nút bên trên mở trao đổi về giải pháp tích hợp, không phải đơn mua thiết bị.The button opens a conversation about the integration, not an order for the device.上方按钮用于沟通集成方案,不是下单购买设备。

Thông số kỹ thuậtSpecifications技术参数

Product TypeProduct TypeProduct Type Computing Device AccessoryComputing Device AccessoryComputing Device Accessory
PDU TypePDU TypePDU Type Local Metered; Auto-Transfer SwitchLocal Metered; Auto-Transfer SwitchLocal Metered; Auto-Transfer Switch
Input PhaseInput PhaseInput Phase Single-PhaseSingle-PhaseSingle-Phase
Input VoltageInput VoltageInput Voltage 200–240V200–240V200–240V
Input ConnectionInput ConnectionInput Connection (2) IEC-320 C14 inlets; 3.66 m (12 ft) input cords(2) IEC-320 C14 inlets; 3.66 m (12 ft) input cords(2) IEC-320 C14 inlets; 3.66 m (12 ft) input cords
Maximum Input CurrentMaximum Input CurrentMaximum Input Current 10A10A10A
Output CapacityOutput CapacityOutput Capacity 2.4kW (240V) / 10A total capacity2.4kW (240V) / 10A total capacity2.4kW (240V) / 10A total capacity
Output ReceptaclesOutput ReceptaclesOutput Receptacles (10) C13(10) C13(10) C13
Output VoltageOutput VoltageOutput Voltage 200–240V200–240V200–240V
FrequencyFrequencyFrequency 50/60 Hz50/60 Hz50/60 Hz
Transfer TimeTransfer TimeTransfer Time 2–5 ms2–5 ms2–5 ms
MountingMountingMounting 1U Rack-Mount, Horizontal1U Rack-Mount, Horizontal1U Rack-Mount, Horizontal
Form FactorForm FactorForm Factor 1U Rackmount; compatible with EIA-standard 19 in. racks1U Rackmount; compatible with EIA-standard 19 in. racks1U Rackmount; compatible with EIA-standard 19 in. racks
DimensionsDimensionsDimensions 43.4 x 440 x 367 mm (1.71 x 17.32 x 14.45 in)43.4 x 440 x 367 mm (1.71 x 17.32 x 14.45 in)43.4 x 440 x 367 mm (1.71 x 17.32 x 14.45 in)
WeightWeightWeight 4.68 kg (10.32 lbs)4.68 kg (10.32 lbs)4.68 kg (10.32 lbs)
Min. Required Rack DepthMin. Required Rack DepthMin. Required Rack Depth 46.48 cm (18.3 in)46.48 cm (18.3 in)46.48 cm (18.3 in)
Operating TemperatureOperating TemperatureOperating Temperature 0° to 40°C (32° to 104°F)0° to 40°C (32° to 104°F)0° to 40°C (32° to 104°F)
Storage TemperatureStorage TemperatureStorage Temperature -30° to 50°C (-22° to 122°F)-30° to 50°C (-22° to 122°F)-30° to 50°C (-22° to 122°F)
Relative HumidityRelative HumidityRelative Humidity 5% to 95% non-condensing5% to 95% non-condensing5% to 95% non-condensing
Operating ElevationOperating ElevationOperating Elevation 0–3000 m (0–10,000 ft)0–3000 m (0–10,000 ft)0–3000 m (0–10,000 ft)
Network Management CardsNetwork Management CardsNetwork Management Cards SNMPWEBCARD; WEBCARDLX; WEBCARDLXE (sold separately)SNMPWEBCARD; WEBCARDLX; WEBCARDLXE (sold separately)SNMPWEBCARD; WEBCARDLX; WEBCARDLXE (sold separately)

Thông số tham khảo từ tài liệu công khai, có thể khác theo phiên bản. Dùng để đối chiếu khi thiết kế giải pháp.Specifications drawn from public documentation; they may vary by version. Use them to compare options while designing a solution.参数来自公开资料,可能因版本而异。用于设计方案时对照。