Eaton Tripp Lite PDUBHV101U 10A Hot-Swap PDU | 6 C13 Outlets, 2 C14 Inlets, 1U Rack/Wall-MountEaton Tripp Lite PDUBHV101U 10A Hot-Swap PDU | 6 C13 Outlets, 2 C14 Inlets, 1U Rack/Wall-MountEaton Tripp Lite PDUBHV101U 10A Hot-Swap PDU | 6 C13 Outlets, 2 C14 Inlets, 1U Rack/Wall-Mount

HãngBrand品牌
Eaton
MãSKU型号
PDUBHV101U
Cách thứcHow it is supplied供应方式
Không bán lẻ. Mua từ hãng hoặc nhà phân phối được ủy quyền.Not sold here. Buy from the manufacturer or an authorised distributor.不在此零售。向厂家或授权经销商购买。

Xem thông tin gốc trên trang của EatonSee the original information on the Eaton website在 Eaton 官网查看原始信息

Đây là website của hãng, mở ở tab mới. MOTION TECH SYSTEM không bán thiết bị này và không nhận hoa hồng từ đường link.This is the manufacturer’s website and opens in a new tab. MOTION TECH SYSTEM does not sell this device and earns no commission from the link.此为厂家网站,在新标签页打开。MOTION TECH SYSTEM 不销售此设备,也不从此链接获得佣金。

Eaton — Computing Device Accessory. Hot-Swap Bypass: Manual transfer switch enables UPS maintenance with less than 8ms transfer time and zero downtime. Inputs: Dual C14 inlets connect to separate UPS and utility power sourcesEaton — Computing Device Accessory. Hot-Swap Bypass: Manual transfer switch enables UPS maintenance with less than 8ms transfer time and zero downtime. Inputs: Dual C14 inlets connect to separate UPS and utility power sourcesEaton — Computing Device Accessory. Hot-Swap Bypass: Manual transfer switch enables UPS maintenance with less than 8ms transfer time and zero downtime. Inputs: Dual C14 inlets connect to separate UPS and utility power sources

  • Hot-Swap Bypass: Manual transfer switch enables UPS maintenance with less than 8ms transfer time and zero downtime
  • Inputs: Dual C14 inlets connect to separate UPS and utility power sources
  • Outlets: 6 C13 outlets with ECO mode power savings and 10A / 2-2.5kW capacity
  • Hot-Swap Bypass: Manual transfer switch enables UPS maintenance with less than 8ms transfer time and zero downtime
  • Inputs: Dual C14 inlets connect to separate UPS and utility power sources
  • Outlets: 6 C13 outlets with ECO mode power savings and 10A / 2-2.5kW capacity
  • Hot-Swap Bypass: Manual transfer switch enables UPS maintenance with less than 8ms transfer time and zero downtime
  • Inputs: Dual C14 inlets connect to separate UPS and utility power sources
  • Outlets: 6 C13 outlets with ECO mode power savings and 10A / 2-2.5kW capacity
Gọi tư vấnCall us电话咨询

Nút bên trên mở trao đổi về giải pháp tích hợp, không phải đơn mua thiết bị.The button opens a conversation about the integration, not an order for the device.上方按钮用于沟通集成方案,不是下单购买设备。

Thông số kỹ thuậtSpecifications技术参数

Product TypeProduct TypeProduct Type Computing Device AccessoryComputing Device AccessoryComputing Device Accessory
PDU TypePDU TypePDU Type Hot-Swap with Manual BypassHot-Swap with Manual BypassHot-Swap with Manual Bypass
Input VoltageInput VoltageInput Voltage 200-250V Single-Phase200-250V Single-Phase200-250V Single-Phase
Maximum Input CurrentMaximum Input CurrentMaximum Input Current 10A10A10A
Input ConnectionsInput ConnectionsInput Connections (2) IEC-320 C14(2) IEC-320 C14(2) IEC-320 C14
Output ReceptaclesOutput ReceptaclesOutput Receptacles (6) IEC-320 C13(6) IEC-320 C13(6) IEC-320 C13
Output CapacityOutput CapacityOutput Capacity 2kW (200V) to 2.5kW (250V) / 10A Max2kW (200V) to 2.5kW (250V) / 10A Max2kW (200V) to 2.5kW (250V) / 10A Max
Frequency CompatibilityFrequency CompatibilityFrequency Compatibility 50 / 60 Hz50 / 60 Hz50 / 60 Hz
Transfer TimeTransfer TimeTransfer Time Less than 8 milliseconds (typical) Break-Before-MakeLess than 8 milliseconds (typical) Break-Before-MakeLess than 8 milliseconds (typical) Break-Before-Make
ECO Power SavingECO Power SavingECO Power Saving Shuts down 5 controlled outlets when master outlet device powers off or enters low-power mode (≤20W)Shuts down 5 controlled outlets when master outlet device powers off or enters low-power mode (≤20W)Shuts down 5 controlled outlets when master outlet device powers off or enters low-power mode (≤20W)
MountingMountingMounting 1U Horizontal Rack-Mount (19-in EIA standard, 2 or 4 post) or Wall-Mount1U Horizontal Rack-Mount (19-in EIA standard, 2 or 4 post) or Wall-Mount1U Horizontal Rack-Mount (19-in EIA standard, 2 or 4 post) or Wall-Mount
Rack HeightRack HeightRack Height 1U1U1U
MaterialMaterialMaterial MetalMetalMetal
DimensionsDimensionsDimensions 43.9 x 437.9 x 100.1 mm (1.73 x 17.24 x 3.94 in)43.9 x 437.9 x 100.1 mm (1.73 x 17.24 x 3.94 in)43.9 x 437.9 x 100.1 mm (1.73 x 17.24 x 3.94 in)
WeightWeightWeight 2.36 kg (5.2 lbs)2.36 kg (5.2 lbs)2.36 kg (5.2 lbs)
Input Cord LengthInput Cord LengthInput Cord Length 1.83 m (6 ft) – (2) C13-to-C14 cables included1.83 m (6 ft) – (2) C13-to-C14 cables included1.83 m (6 ft) – (2) C13-to-C14 cables included
Operating TemperatureOperating TemperatureOperating Temperature 0° to 40°C (32° to 104°F)0° to 40°C (32° to 104°F)0° to 40°C (32° to 104°F)
Storage TemperatureStorage TemperatureStorage Temperature -30° to 50°C (-22° to 122°F)-30° to 50°C (-22° to 122°F)-30° to 50°C (-22° to 122°F)
Relative HumidityRelative HumidityRelative Humidity 5% to 95% non-condensing5% to 95% non-condensing5% to 95% non-condensing
Operating ElevationOperating ElevationOperating Elevation 0-3000 m (0-10,000 ft)0-3000 m (0-10,000 ft)0-3000 m (0-10,000 ft)
CertificationsCertificationsCertifications UL 62368-1, CAN/CSA-C22.2 No. 62368-1, NOM, CE, UKCA, RoHSUL 62368-1, CAN/CSA-C22.2 No. 62368-1, NOM, CE, UKCA, RoHSUL 62368-1, CAN/CSA-C22.2 No. 62368-1, NOM, CE, UKCA, RoHS

Thông số tham khảo từ tài liệu công khai, có thể khác theo phiên bản. Dùng để đối chiếu khi thiết kế giải pháp.Specifications drawn from public documentation; they may vary by version. Use them to compare options while designing a solution.参数来自公开资料,可能因版本而异。用于设计方案时对照。