Eaton EVMI4609X-06 17.3kW 42-Outlet 3-Phase Metered PDU 0U VerticalEaton EVMI4609X-06 17.3kW 42-Outlet 3-Phase Metered PDU 0U VerticalEaton EVMI4609X-06 17.3kW 42-Outlet 3-Phase Metered PDU 0U Vertical

HãngBrand品牌
Eaton
MãSKU型号
EVMI4609X-06
Cách thứcHow it is supplied供应方式
Không bán lẻ. Mua từ hãng hoặc nhà phân phối được ủy quyền.Not sold here. Buy from the manufacturer or an authorised distributor.不在此零售。向厂家或授权经销商购买。

Xem thông tin gốc trên trang của EatonSee the original information on the Eaton website在 Eaton 官网查看原始信息

Đây là website của hãng, mở ở tab mới. MOTION TECH SYSTEM không bán thiết bị này và không nhận hoa hồng từ đường link.This is the manufacturer’s website and opens in a new tab. MOTION TECH SYSTEM does not sell this device and earns no commission from the link.此为厂家网站,在新标签页打开。MOTION TECH SYSTEM 不销售此设备,也不从此链接获得佣金。

Eaton — Computing Device Accessory. Capacity: 17.3 kW, 3-Phase 208V with 48A max input and 42 outlets (24 C13 + 18 C39). Security: Embedded hot-swappable Gigabit Network Module G4 with zero-trust architectureEaton — Computing Device Accessory. Capacity: 17.3 kW, 3-Phase 208V with 48A max input and 42 outlets (24 C13 + 18 C39). Security: Embedded hot-swappable Gigabit Network Module G4 with zero-trust architectureEaton — Computing Device Accessory. Capacity: 17.3 kW, 3-Phase 208V with 48A max input and 42 outlets (24 C13 + 18 C39). Security: Embedded hot-swappable Gigabit Network Module G4 with zero-trust architecture

  • Capacity: 17.3 kW, 3-Phase 208V with 48A max input and 42 outlets (24 C13 + 18 C39)
  • Security: Embedded hot-swappable Gigabit Network Module G4 with zero-trust architecture
  • Form Factor: 0U Vertical, 2-inch wide, toolless mount; cascade up to 40 PDUs from one network point
  • Capacity: 17.3 kW, 3-Phase 208V with 48A max input and 42 outlets (24 C13 + 18 C39)
  • Security: Embedded hot-swappable Gigabit Network Module G4 with zero-trust architecture
  • Form Factor: 0U Vertical, 2-inch wide, toolless mount; cascade up to 40 PDUs from one network point
  • Capacity: 17.3 kW, 3-Phase 208V with 48A max input and 42 outlets (24 C13 + 18 C39)
  • Security: Embedded hot-swappable Gigabit Network Module G4 with zero-trust architecture
  • Form Factor: 0U Vertical, 2-inch wide, toolless mount; cascade up to 40 PDUs from one network point
Gọi tư vấnCall us电话咨询

Nút bên trên mở trao đổi về giải pháp tích hợp, không phải đơn mua thiết bị.The button opens a conversation about the integration, not an order for the device.上方按钮用于沟通集成方案,不是下单购买设备。

Thông số kỹ thuậtSpecifications技术参数

Product TypeProduct TypeProduct Type Computing Device AccessoryComputing Device AccessoryComputing Device Accessory
PDU TypePDU TypePDU Type 3-Phase Metered Input3-Phase Metered Input3-Phase Metered Input
Input VoltageInput VoltageInput Voltage 208V AC, 3-Phase208V AC, 3-Phase208V AC, 3-Phase
Input ConnectionInput ConnectionInput Connection 460P9W, 6 ft. (1.83 m) cord460P9W, 6 ft. (1.83 m) cord460P9W, 6 ft. (1.83 m) cord
Maximum Input CurrentMaximum Input CurrentMaximum Input Current 60A60A60A
Output CapacityOutput CapacityOutput Capacity 17.3 kW / 48A max per output phase17.3 kW / 48A max per output phase17.3 kW / 48A max per output phase
Output ReceptaclesOutput ReceptaclesOutput Receptacles (24) C13, (18) C39 (accepts C14 and C20); Compatible with P-Lock Power Cords(24) C13, (18) C39 (accepts C14 and C20); Compatible with P-Lock Power Cords(24) C13, (18) C39 (accepts C14 and C20); Compatible with P-Lock Power Cords
Overload ProtectionOverload ProtectionOverload Protection (6) 2-pole 20A low-profile circuit breakers, one per outlet bank(6) 2-pole 20A low-profile circuit breakers, one per outlet bank(6) 2-pole 20A low-profile circuit breakers, one per outlet bank
FrequencyFrequencyFrequency 50/60 Hz50/60 Hz50/60 Hz
Measurement AccuracyMeasurement AccuracyMeasurement Accuracy +/-1% for current, voltage, and power+/-1% for current, voltage, and power+/-1% for current, voltage, and power
Form FactorForm FactorForm Factor 0U Vertical0U Vertical0U Vertical
DimensionsDimensionsDimensions 1828.8 x 50.8 x 65.0 mm (72.0 x 2.0 x 2.56 in)1828.8 x 50.8 x 65.0 mm (72.0 x 2.0 x 2.56 in)1828.8 x 50.8 x 65.0 mm (72.0 x 2.0 x 2.56 in)
WeightWeightWeight 11.50 kg (25.35 lbs)11.50 kg (25.35 lbs)11.50 kg (25.35 lbs)
MaterialMaterialMaterial AluminumAluminumAluminum
MountingMountingMounting Toolless shoulder-style or flush-style mounting buttons, 0U vertical in 42U rackToolless shoulder-style or flush-style mounting buttons, 0U vertical in 42U rackToolless shoulder-style or flush-style mounting buttons, 0U vertical in 42U rack
Network ModuleNetwork ModuleNetwork Module Eaton Gigabit Network Module G4 (hot-swappable), 10/100/1000 MbpsEaton Gigabit Network Module G4 (hot-swappable), 10/100/1000 MbpsEaton Gigabit Network Module G4 (hot-swappable), 10/100/1000 Mbps
InterfacesInterfacesInterfaces Ethernet, SerialEthernet, SerialEthernet, Serial
Daisy-ChainDaisy-ChainDaisy-Chain Cascade up to 40 PDUs, each with individual IP addressCascade up to 40 PDUs, each with individual IP addressCascade up to 40 PDUs, each with individual IP address
SNMPSNMPSNMP YesYesYes
Operating TemperatureOperating TemperatureOperating Temperature 0° to 60°C (32° to 140°F)0° to 60°C (32° to 140°F)0° to 60°C (32° to 140°F)
Relative HumidityRelative HumidityRelative Humidity 5% to 95% non-condensing5% to 95% non-condensing5% to 95% non-condensing
Operating ElevationOperating ElevationOperating Elevation 0–3,000 m (0–10,000 ft)0–3,000 m (0–10,000 ft)0–3,000 m (0–10,000 ft)