Đây là thư viện để kỹ sư đối chiếu khi thiết kế giải pháp tích hợp. MOTION TECH SYSTEM không bán lẻ từng thiết bị và không giữ các máy này trong kho.This library is for engineers comparing equipment while designing an integrated solution. MOTION TECH SYSTEM does not retail individual devices and does not stock them.本目录供工程师在设计集成方案时对照设备。MOTION TECH SYSTEM 不零售单台设备,也不库存这些机器。

298 sản phẩm298 products298 个产品

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVN6H50BA 14.5kW 42-Outlet Monitored PDU 0U Vertical Hubbell CS8365CEaton Tripp Lite PDU3EVN6H50BA 14.5kW 42-Outlet Monitored PDU 0U Vertical Hubbell CS8365CEaton Tripp Lite PDU3EVN6H50BA 14.5kW 42-Outlet Monitored PDU 0U Vertical Hubbell CS8365C

Eaton · PDU3EVN6H50BA

Eaton — Computing Device Accessory. Capacity: 14.5kW 3-Phase, 42 Outlets (30 C13 + 12 C19), 200-240V. Monitoring: Built-in GbE WEBCARDLX, ±1% billing-grade accuracy, touchscreen LCDEaton — Computing Device Accessory. Capacity: 14.5kW 3-Phase, 42 Outlets (30 C13 + 12 C19), 200-240V. Monitoring: Built-in GbE WEBCARDLX, ±1% billing-grade accuracy, touchscreen LCDEaton — Computing Device Accessory. Capacity: 14.5kW 3-Phase, 42 Outlets (30 C13 + 12 C19), 200-240V. Monitoring: Built-in GbE WEBCARDLX, ±1% billing-grade accuracy, touchscreen LCD

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVN6L1520 6.6kW Monitored PDU | 48 Outlets | 0U VerticalEaton Tripp Lite PDU3EVN6L1520 6.6kW Monitored PDU | 48 Outlets | 0U VerticalEaton Tripp Lite PDU3EVN6L1520 6.6kW Monitored PDU | 48 Outlets | 0U Vertical

Eaton · PDU3EVN6L1520

Eaton — Computing Device Accessory. Capacity: 6.6kW 3-Phase output with 42 C13 and 6 C19 outlets across 3 monitored load banks. Management: Built-in GbE WEBCARDLX with PADM20, SNMP, SSH, HTML5 remote access 24/7Eaton — Computing Device Accessory. Capacity: 6.6kW 3-Phase output with 42 C13 and 6 C19 outlets across 3 monitored load banks. Management: Built-in GbE WEBCARDLX with PADM20, SNMP, SSH, HTML5 remote access 24/7Eaton — Computing Device Accessory. Capacity: 6.6kW 3-Phase output with 42 C13 and 6 C19 outlets across 3 monitored load banks. Management: Built-in GbE WEBCARDLX with PADM20, SNMP, SSH, HTML5 remote access 24/7

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVN6L2120 5.8kW 45-Outlet 3-Phase Monitored PDU 0U VerticalEaton Tripp Lite PDU3EVN6L2120 5.8kW 45-Outlet 3-Phase Monitored PDU 0U VerticalEaton Tripp Lite PDU3EVN6L2120 5.8kW 45-Outlet 3-Phase Monitored PDU 0U Vertical

Eaton · PDU3EVN6L2120

Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase Monitored PDU with 45 outlets (36x C13, 6x C19, 3x NEMA 5-15/20R). Monitoring: Built-in GbE WEBCARDLX with PADM20, color touchscreen LCD, ±1% billing-grade accuracyEaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase Monitored PDU with 45 outlets (36x C13, 6x C19, 3x NEMA 5-15/20R). Monitoring: Built-in GbE WEBCARDLX with PADM20, color touchscreen LCD, ±1% billing-grade accuracyEaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase Monitored PDU with 45 outlets (36x C13, 6x C19, 3x NEMA 5-15/20R). Monitoring: Built-in GbE WEBCARDLX with PADM20, color touchscreen LCD, ±1% billing-grade accuracy

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVN6L2130 8.6kW 45-Outlet Monitored PDU 0U VerticalEaton Tripp Lite PDU3EVN6L2130 8.6kW 45-Outlet Monitored PDU 0U VerticalEaton Tripp Lite PDU3EVN6L2130 8.6kW 45-Outlet Monitored PDU 0U Vertical

Eaton · PDU3EVN6L2130

Eaton — Computing Device Accessory. Capacity: 8.6kW 208/120V 3-Phase with 45 outlets (36 C13, 6 C19, 3 NEMA 5-15/20R). Monitoring: Gigabit LX network interface with ±1% billing-grade accuracy via SNMP, SSH, HTTPSEaton — Computing Device Accessory. Capacity: 8.6kW 208/120V 3-Phase with 45 outlets (36 C13, 6 C19, 3 NEMA 5-15/20R). Monitoring: Gigabit LX network interface with ±1% billing-grade accuracy via SNMP, SSH, HTTPSEaton — Computing Device Accessory. Capacity: 8.6kW 208/120V 3-Phase with 45 outlets (36 C13, 6 C19, 3 NEMA 5-15/20R). Monitoring: Gigabit LX network interface with ±1% billing-grade accuracy via SNMP, SSH, HTTPS

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVN6L2130B 10kW 200-240V Monitored PDU | 48 Outlets | NEMA L21-30P Input | 0U VerticalEaton Tripp Lite PDU3EVN6L2130B 10kW 200-240V Monitored PDU | 48 Outlets | NEMA L21-30P Input | 0U VerticalEaton Tripp Lite PDU3EVN6L2130B 10kW 200-240V Monitored PDU | 48 Outlets | NEMA L21-30P Input | 0U Vertical

Eaton · PDU3EVN6L2130B

Eaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with 48 outlets (42 C13, 6 C19) across 3 breakered load banks. Monitoring: Built-in GbE WEBCARDLX with touchscreen LCD, SNMP, SSH, and QR code mobile accessEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with 48 outlets (42 C13, 6 C19) across 3 breakered load banks. Monitoring: Built-in GbE WEBCARDLX with touchscreen LCD, SNMP, SSH, and QR code mobile accessEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with 48 outlets (42 C13, 6 C19) across 3 breakered load banks. Monitoring: Built-in GbE WEBCARDLX with touchscreen LCD, SNMP, SSH, and QR code mobile access

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVNR6H50A 14.4kW 18-Outlet Monitored PDU 0U VerticalEaton Tripp Lite PDU3EVNR6H50A 14.4kW 18-Outlet Monitored PDU 0U VerticalEaton Tripp Lite PDU3EVNR6H50A 14.4kW 18-Outlet Monitored PDU 0U Vertical

Eaton · PDU3EVNR6H50A

Eaton — Computing Device Accessory. Capacity: 14.4kW 3-Phase, 18 Outlets (6x C13, 12x C19) with six 20A breakered load banks. Monitoring: Per-outlet current metering with ±1% billing-grade accuracy via built-in GbE WEBCARDLXEaton — Computing Device Accessory. Capacity: 14.4kW 3-Phase, 18 Outlets (6x C13, 12x C19) with six 20A breakered load banks. Monitoring: Per-outlet current metering with ±1% billing-grade accuracy via built-in GbE WEBCARDLXEaton — Computing Device Accessory. Capacity: 14.4kW 3-Phase, 18 Outlets (6x C13, 12x C19) with six 20A breakered load banks. Monitoring: Per-outlet current metering with ±1% billing-grade accuracy via built-in GbE WEBCARDLX

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVNR6L2130 10kW 30-Outlet Monitored PDU 0U Rack-Mount Gigabit LX InterfaceEaton Tripp Lite PDU3EVNR6L2130 10kW 30-Outlet Monitored PDU 0U Rack-Mount Gigabit LX InterfaceEaton Tripp Lite PDU3EVNR6L2130 10kW 30-Outlet Monitored PDU 0U Rack-Mount Gigabit LX Interface

Eaton · PDU3EVNR6L2130

Eaton — Computing Device Accessory. Capacity: 10kW 3-Phase, 30 Outlets (24 C13 + 6 C19), 200-240V. Monitoring: Per-outlet current metering with ±1% billing-grade accuracyEaton — Computing Device Accessory. Capacity: 10kW 3-Phase, 30 Outlets (24 C13 + 6 C19), 200-240V. Monitoring: Per-outlet current metering with ±1% billing-grade accuracyEaton — Computing Device Accessory. Capacity: 10kW 3-Phase, 30 Outlets (24 C13 + 6 C19), 200-240V. Monitoring: Per-outlet current metering with ±1% billing-grade accuracy

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVS6L2120 6.7kW Switched PDU | L21-20P Input | 30 Outlets | 0U VerticalEaton Tripp Lite PDU3EVS6L2120 6.7kW Switched PDU | L21-20P Input | 30 Outlets | 0U VerticalEaton Tripp Lite PDU3EVS6L2120 6.7kW Switched PDU | L21-20P Input | 30 Outlets | 0U Vertical

Eaton · PDU3EVS6L2120

Eaton — Computing Device Accessory. Capacity: 6.7kW 3-Phase Switched PDU with 30 outlets (24 C13, 6 C19). Management: Built-in GbE WEBCARDLX with PADM20, SNMP V1/V2c/V3, Auto Probe rebootEaton — Computing Device Accessory. Capacity: 6.7kW 3-Phase Switched PDU with 30 outlets (24 C13, 6 C19). Management: Built-in GbE WEBCARDLX with PADM20, SNMP V1/V2c/V3, Auto Probe rebootEaton — Computing Device Accessory. Capacity: 6.7kW 3-Phase Switched PDU with 30 outlets (24 C13, 6 C19). Management: Built-in GbE WEBCARDLX with PADM20, SNMP V1/V2c/V3, Auto Probe reboot

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVS6L2130 10kW Switched 30-Outlet 0U PDUEaton Tripp Lite PDU3EVS6L2130 10kW Switched 30-Outlet 0U PDUEaton Tripp Lite PDU3EVS6L2130 10kW Switched 30-Outlet 0U PDU

Eaton · PDU3EVS6L2130

Eaton — Computing Device Accessory. Capacity: 10kW Switched 3-Phase PDU, 24A max input (NEMA L21-30P). Outlets: 24 x C13 and 6 x C19 individually controllable 200-240V outletsEaton — Computing Device Accessory. Capacity: 10kW Switched 3-Phase PDU, 24A max input (NEMA L21-30P). Outlets: 24 x C13 and 6 x C19 individually controllable 200-240V outletsEaton — Computing Device Accessory. Capacity: 10kW Switched 3-Phase PDU, 24A max input (NEMA L21-30P). Outlets: 24 x C13 and 6 x C19 individually controllable 200-240V outlets

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVSR10L1530 10kW 30-Outlet 3-Phase Switched PDU 0U VerticalEaton Tripp Lite PDU3EVSR10L1530 10kW 30-Outlet 3-Phase Switched PDU 0U VerticalEaton Tripp Lite PDU3EVSR10L1530 10kW 30-Outlet 3-Phase Switched PDU 0U Vertical

Eaton · PDU3EVSR10L1530

Eaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with 30 Individually Switched Outlets (24 C13, 6 C19). Monitoring: ±1% Billing-Grade Accuracy with Color Touchscreen LCD and QR Code Mobile AccessEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with 30 Individually Switched Outlets (24 C13, 6 C19). Monitoring: ±1% Billing-Grade Accuracy with Color Touchscreen LCD and QR Code Mobile AccessEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with 30 Individually Switched Outlets (24 C13, 6 C19). Monitoring: ±1% Billing-Grade Accuracy with Color Touchscreen LCD and QR Code Mobile Access

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVSR10L2130 10kW 30-Outlet Switched 0U Vertical PDUEaton Tripp Lite PDU3EVSR10L2130 10kW 30-Outlet Switched 0U Vertical PDUEaton Tripp Lite PDU3EVSR10L2130 10kW 30-Outlet Switched 0U Vertical PDU

Eaton · PDU3EVSR10L2130

Eaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with NEMA L21-30P input and 3.05 m (10 ft) cord. Outlets: 30 individually switched outlets - 24 C13, 6 C19 across 3 breakered load banksEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with NEMA L21-30P input and 3.05 m (10 ft) cord. Outlets: 30 individually switched outlets - 24 C13, 6 C19 across 3 breakered load banksEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase with NEMA L21-30P input and 3.05 m (10 ft) cord. Outlets: 30 individually switched outlets - 24 C13, 6 C19 across 3 breakered load banks

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVSR1G60 12.6kW 3-Phase Managed PDU | 36-Outlet 0U IsoBreaker Rack-MountEaton Tripp Lite PDU3EVSR1G60 12.6kW 3-Phase Managed PDU | 36-Outlet 0U IsoBreaker Rack-MountEaton Tripp Lite PDU3EVSR1G60 12.6kW 3-Phase Managed PDU | 36-Outlet 0U IsoBreaker Rack-Mount

Eaton · PDU3EVSR1G60

Eaton — Computing Device Accessory. Capacity: 12.6 kW 3-Phase output with 35A max input via IEC-60309 60A Blue (3P+E). Outlets: 30 x C13 and 6 x C19 individually controllable 200-240V outlets with IsoBreaker technologyEaton — Computing Device Accessory. Capacity: 12.6 kW 3-Phase output with 35A max input via IEC-60309 60A Blue (3P+E). Outlets: 30 x C13 and 6 x C19 individually controllable 200-240V outlets with IsoBreaker technologyEaton — Computing Device Accessory. Capacity: 12.6 kW 3-Phase output with 35A max input via IEC-60309 60A Blue (3P+E). Outlets: 30 x C13 and 6 x C19 individually controllable 200-240V outlets with IsoBreaker technology

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVSR6H50 14.5kW 30-Outlet Switched 3-Phase PDU 0U VerticalEaton Tripp Lite PDU3EVSR6H50 14.5kW 30-Outlet Switched 3-Phase PDU 0U VerticalEaton Tripp Lite PDU3EVSR6H50 14.5kW 30-Outlet Switched 3-Phase PDU 0U Vertical

Eaton · PDU3EVSR6H50

Eaton — Computing Device Accessory. Capacity: 14.5kW 200-240V 3-Phase Switched PDU with 30 individually controllable outlets. Outlets: 24 x C13 and 6 x C19 switched outlets with plug-lock sleeves and 3 x 20A breakersEaton — Computing Device Accessory. Capacity: 14.5kW 200-240V 3-Phase Switched PDU with 30 individually controllable outlets. Outlets: 24 x C13 and 6 x C19 switched outlets with plug-lock sleeves and 3 x 20A breakersEaton — Computing Device Accessory. Capacity: 14.5kW 200-240V 3-Phase Switched PDU with 30 individually controllable outlets. Outlets: 24 x C13 and 6 x C19 switched outlets with plug-lock sleeves and 3 x 20A breakers

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVSR6L1520 6.7kW 30-Outlet Switched PDU | L15-20P Input | 0U Vertical | TAAEaton Tripp Lite PDU3EVSR6L1520 6.7kW 30-Outlet Switched PDU | L15-20P Input | 0U Vertical | TAAEaton Tripp Lite PDU3EVSR6L1520 6.7kW 30-Outlet Switched PDU | L15-20P Input | 0U Vertical | TAA

Eaton · PDU3EVSR6L1520

Eaton — Computing Device Accessory. Capacity: 6.7kW 3-Phase Switched PDU with 30 individually controllable outlets (24 C13, 6 C19). Management: Built-in GbE WEBCARDLX with PADM20, Auto Probe reboot, remote outlet controlEaton — Computing Device Accessory. Capacity: 6.7kW 3-Phase Switched PDU with 30 individually controllable outlets (24 C13, 6 C19). Management: Built-in GbE WEBCARDLX with PADM20, Auto Probe reboot, remote outlet controlEaton — Computing Device Accessory. Capacity: 6.7kW 3-Phase Switched PDU with 30 individually controllable outlets (24 C13, 6 C19). Management: Built-in GbE WEBCARDLX with PADM20, Auto Probe reboot, remote outlet control

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3EVSR6L2130 10kW 30-Outlet Switched 3-Phase PDU 0U VerticalEaton Tripp Lite PDU3EVSR6L2130 10kW 30-Outlet Switched 3-Phase PDU 0U VerticalEaton Tripp Lite PDU3EVSR6L2130 10kW 30-Outlet Switched 3-Phase PDU 0U Vertical

Eaton · PDU3EVSR6L2130

Eaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase switched PDU with 30 individually controllable outlets (24 C13, 6 C19). Network Control: Built-in GbE LX Platform interface with SNMPv1/v2c/v3, HTTPS, SSH, and PowerAlert Device ManagerEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase switched PDU with 30 individually controllable outlets (24 C13, 6 C19). Network Control: Built-in GbE LX Platform interface with SNMPv1/v2c/v3, HTTPS, SSH, and PowerAlert Device ManagerEaton — Computing Device Accessory. Capacity: 10kW 200-240V 3-Phase switched PDU with 30 individually controllable outlets (24 C13, 6 C19). Network Control: Built-in GbE LX Platform interface with SNMPv1/v2c/v3, HTTPS, SSH, and PowerAlert Device Manager

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6H50 12.6kW 3-Phase Local Metered PDU | 36 C13, 9 C19 Outlets | 6 ft Cord | 0U VerticalEaton Tripp Lite PDU3MV6H50 12.6kW 3-Phase Local Metered PDU | 36 C13, 9 C19 Outlets | 6 ft Cord | 0U VerticalEaton Tripp Lite PDU3MV6H50 12.6kW 3-Phase Local Metered PDU | 36 C13, 9 C19 Outlets | 6 ft Cord | 0U Vertical

Eaton · PDU3MV6H50

Eaton — Computing Device Accessory. Capacity: 12.6kW 3-Phase 208V with 45 total outlets (36 C13, 9 C19). Metering: 3 built-in digital current meters report load per output phaseEaton — Computing Device Accessory. Capacity: 12.6kW 3-Phase 208V with 45 total outlets (36 C13, 9 C19). Metering: 3 built-in digital current meters report load per output phaseEaton — Computing Device Accessory. Capacity: 12.6kW 3-Phase 208V with 45 total outlets (36 C13, 9 C19). Metering: 3 built-in digital current meters report load per output phase

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6H50A 14.4kW Local Metered PDU | 36 C13, 6 C19, 3 L6-30R Outlets | 0U Vertical Rack-MountEaton Tripp Lite PDU3MV6H50A 14.4kW Local Metered PDU | 36 C13, 6 C19, 3 L6-30R Outlets | 0U Vertical Rack-MountEaton Tripp Lite PDU3MV6H50A 14.4kW Local Metered PDU | 36 C13, 6 C19, 3 L6-30R Outlets | 0U Vertical Rack-Mount

Eaton · PDU3MV6H50A

Eaton — Computing Device Accessory. Capacity: 14.4kW 3-Phase 208V with 50A Hubbell CS8365C input. Outlets: 45 total - 36 C13, 6 C19, 3 L6-30R in 3 breakered load banksEaton — Computing Device Accessory. Capacity: 14.4kW 3-Phase 208V with 50A Hubbell CS8365C input. Outlets: 45 total - 36 C13, 6 C19, 3 L6-30R in 3 breakered load banksEaton — Computing Device Accessory. Capacity: 14.4kW 3-Phase 208V with 50A Hubbell CS8365C input. Outlets: 45 total - 36 C13, 6 C19, 3 L6-30R in 3 breakered load banks

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6L2120 5.7kW 48-Outlet Local Metered PDU 0U VerticalEaton Tripp Lite PDU3MV6L2120 5.7kW 48-Outlet Local Metered PDU 0U VerticalEaton Tripp Lite PDU3MV6L2120 5.7kW 48-Outlet Local Metered PDU 0U Vertical

Eaton · PDU3MV6L2120

Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase 208/120V with 48 total outlets. Outlets: (36) C13 (208V), (6) C19 (208V), (6) 5-15/20R (120V)Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase 208/120V with 48 total outlets. Outlets: (36) C13 (208V), (6) C19 (208V), (6) 5-15/20R (120V)Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase 208/120V with 48 total outlets. Outlets: (36) C13 (208V), (6) C19 (208V), (6) 5-15/20R (120V)

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6L2120B 5.7kW 27-Outlet Local Metered PDU 0U VerticalEaton Tripp Lite PDU3MV6L2120B 5.7kW 27-Outlet Local Metered PDU 0U VerticalEaton Tripp Lite PDU3MV6L2120B 5.7kW 27-Outlet Local Metered PDU 0U Vertical

Eaton · PDU3MV6L2120B

Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase 208/120V local metered PDU. Outlets: 21 x NEMA 5-15/20R (120V) and 6 x NEMA L6-20R (208V), 27 totalEaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase 208/120V local metered PDU. Outlets: 21 x NEMA 5-15/20R (120V) and 6 x NEMA L6-20R (208V), 27 totalEaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase 208/120V local metered PDU. Outlets: 21 x NEMA 5-15/20R (120V) and 6 x NEMA L6-20R (208V), 27 total

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6L2120LV 5.7kW 42-Outlet 3-Phase Local Metered PDU 0U VerticalEaton Tripp Lite PDU3MV6L2120LV 5.7kW 42-Outlet 3-Phase Local Metered PDU 0U VerticalEaton Tripp Lite PDU3MV6L2120LV 5.7kW 42-Outlet 3-Phase Local Metered PDU 0U Vertical

Eaton · PDU3MV6L2120LV

Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase output, 16A max per phase, 42 NEMA 5-15/20R outlets. Monitoring: 3 built-in digital current meters reporting load per phase (L1, L2, L3)Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase output, 16A max per phase, 42 NEMA 5-15/20R outlets. Monitoring: 3 built-in digital current meters reporting load per phase (L1, L2, L3)Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase output, 16A max per phase, 42 NEMA 5-15/20R outlets. Monitoring: 3 built-in digital current meters reporting load per phase (L1, L2, L3)

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6L2130 8.6kW 3-Phase Local Metered PDU 48-Outlet 0U VerticalEaton Tripp Lite PDU3MV6L2130 8.6kW 3-Phase Local Metered PDU 48-Outlet 0U VerticalEaton Tripp Lite PDU3MV6L2130 8.6kW 3-Phase Local Metered PDU 48-Outlet 0U Vertical

Eaton · PDU3MV6L2130

Eaton — Computing Device Accessory. Capacity: 8.6kW 3-Phase 208/120V with NEMA L21-30P 30A input and 6 ft. cord. Outlets: 48 total - 36 C13 (208V), 6 C19 (208V), 6 NEMA 5-15/20R (120V)Eaton — Computing Device Accessory. Capacity: 8.6kW 3-Phase 208/120V with NEMA L21-30P 30A input and 6 ft. cord. Outlets: 48 total - 36 C13 (208V), 6 C19 (208V), 6 NEMA 5-15/20R (120V)Eaton — Computing Device Accessory. Capacity: 8.6kW 3-Phase 208/120V with NEMA L21-30P 30A input and 6 ft. cord. Outlets: 48 total - 36 C13 (208V), 6 C19 (208V), 6 NEMA 5-15/20R (120V)

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3MV6L2130A 8.6kW 45-Outlet 3-Phase Local Metered PDU | NEMA L21-30P Input 0U VerticalEaton Tripp Lite PDU3MV6L2130A 8.6kW 45-Outlet 3-Phase Local Metered PDU | NEMA L21-30P Input 0U VerticalEaton Tripp Lite PDU3MV6L2130A 8.6kW 45-Outlet 3-Phase Local Metered PDU | NEMA L21-30P Input 0U Vertical

Eaton · PDU3MV6L2130A

Eaton — Computing Device Accessory. Capacity: 8.6 kW 3-Phase 208V with 45 outlets (36 C13, 9 C19). Metering: 3 digital current meters report live load per output phaseEaton — Computing Device Accessory. Capacity: 8.6 kW 3-Phase 208V with 45 outlets (36 C13, 9 C19). Metering: 3 digital current meters report live load per output phaseEaton — Computing Device Accessory. Capacity: 8.6 kW 3-Phase 208V with 45 outlets (36 C13, 9 C19). Metering: 3 digital current meters report live load per output phase

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3V6L2120LV 5.7kW 42-Outlet 3-Phase Basic PDU 0U Vertical Rack-MountEaton Tripp Lite PDU3V6L2120LV 5.7kW 42-Outlet 3-Phase Basic PDU 0U Vertical Rack-MountEaton Tripp Lite PDU3V6L2120LV 5.7kW 42-Outlet 3-Phase Basic PDU 0U Vertical Rack-Mount

Eaton · PDU3V6L2120LV

Eaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase power distribution. Outlets: 42 NEMA 5-15/20R 120V outlets across 3 single-phase load banksEaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase power distribution. Outlets: 42 NEMA 5-15/20R 120V outlets across 3 single-phase load banksEaton — Computing Device Accessory. Capacity: 5.7kW 3-Phase power distribution. Outlets: 42 NEMA 5-15/20R 120V outlets across 3 single-phase load banks

Chi tiếtDetails详情 →

Tham chiếuReference参考

Power Distribution Units (PDUs)Power Distribution Units (PDUs)Power Distribution Units (PDUs)

Eaton Tripp Lite PDU3V6L2130 8.6kW 48-Outlet Basic PDU 0U Rack-MountEaton Tripp Lite PDU3V6L2130 8.6kW 48-Outlet Basic PDU 0U Rack-MountEaton Tripp Lite PDU3V6L2130 8.6kW 48-Outlet Basic PDU 0U Rack-Mount

Eaton · PDU3V6L2130

Eaton — Computing Device Accessory. Capacity: 8.6 kW 3-Phase 208/120V output. Outlets: 36 C13, 6 C19 (208V) and 6 NEMA 5-15/20R (120V) - 48 totalEaton — Computing Device Accessory. Capacity: 8.6 kW 3-Phase 208/120V output. Outlets: 36 C13, 6 C19 (208V) and 6 NEMA 5-15/20R (120V) - 48 totalEaton — Computing Device Accessory. Capacity: 8.6 kW 3-Phase 208/120V output. Outlets: 36 C13, 6 C19 (208V) and 6 NEMA 5-15/20R (120V) - 48 total

Chi tiếtDetails详情 →

Cần một giải pháp, không mua lẻ từng máy?Need a solution, not a single device?需要的是方案,而不是单买一台设备?

Kỹ sư khảo sát hiện trường và thiết kế phần tích hợp. Thiết bị trong thư viện chỉ để tham chiếu; máy được mua từ hãng hoặc nhà phân phối được ủy quyền.Engineers survey the site and design the integration. Devices in this library are references only; the hardware is purchased from the manufacturer or an authorised distributor.工程师现场勘察并设计集成。目录中的设备仅供参考;硬件向厂家或授权经销商购买。