Eaton Tripp Lite PDUMNH20HVAT1 3.8kW ATS Monitored PDU | 8 C13, 2 C19 Outlets | Dual C20 Inlets | 12 ft Cords | 1U Rack-MountEaton Tripp Lite PDUMNH20HVAT1 3.8kW ATS Monitored PDU | 8 C13, 2 C19 Outlets | Dual C20 Inlets | 12 ft Cords | 1U Rack-MountEaton Tripp Lite PDUMNH20HVAT1 3.8kW ATS Monitored PDU | 8 C13, 2 C19 Outlets | Dual C20 Inlets | 12 ft Cords | 1U Rack-Mount

HãngBrand品牌
Eaton
MãSKU型号
PDUMNH20HVAT1
Cách thứcHow it is supplied供应方式
Không bán lẻ. Mua từ hãng hoặc nhà phân phối được ủy quyền.Not sold here. Buy from the manufacturer or an authorised distributor.不在此零售。向厂家或授权经销商购买。

Xem thông tin gốc trên trang của EatonSee the original information on the Eaton website在 Eaton 官网查看原始信息

Đây là website của hãng, mở ở tab mới. MOTION TECH SYSTEM không bán thiết bị này và không nhận hoa hồng từ đường link.This is the manufacturer’s website and opens in a new tab. MOTION TECH SYSTEM does not sell this device and earns no commission from the link.此为厂家网站,在新标签页打开。MOTION TECH SYSTEM 不销售此设备,也不从此链接获得佣金。

Eaton — Computing Device Accessory. ATS Redundancy: Switches from primary to secondary power source in <7 ms. Outlets: 8 x C13 + 2 x C19, 200-240V | Dual C20 Inlets, 12 ft cordsEaton — Computing Device Accessory. ATS Redundancy: Switches from primary to secondary power source in <7 ms. Outlets: 8 x C13 + 2 x C19, 200-240V | Dual C20 Inlets, 12 ft cordsEaton — Computing Device Accessory. ATS Redundancy: Switches from primary to secondary power source in <7 ms. Outlets: 8 x C13 + 2 x C19, 200-240V | Dual C20 Inlets, 12 ft cords

  • ATS Redundancy: Switches from primary to secondary power source in <7 ms
  • Outlets: 8 x C13 + 2 x C19, 200-240V | Dual C20 Inlets, 12 ft cords
  • Remote Monitoring: Built-in WEBCARDLX with SNMP, SSH, HTML5 web interface
  • ATS Redundancy: Switches from primary to secondary power source in <7 ms
  • Outlets: 8 x C13 + 2 x C19, 200-240V | Dual C20 Inlets, 12 ft cords
  • Remote Monitoring: Built-in WEBCARDLX with SNMP, SSH, HTML5 web interface
  • ATS Redundancy: Switches from primary to secondary power source in <7 ms
  • Outlets: 8 x C13 + 2 x C19, 200-240V | Dual C20 Inlets, 12 ft cords
  • Remote Monitoring: Built-in WEBCARDLX with SNMP, SSH, HTML5 web interface
Gọi tư vấnCall us电话咨询

Nút bên trên mở trao đổi về giải pháp tích hợp, không phải đơn mua thiết bị.The button opens a conversation about the integration, not an order for the device.上方按钮用于沟通集成方案,不是下单购买设备。

Thông số kỹ thuậtSpecifications技术参数

Product TypeProduct TypeProduct Type Computing Device AccessoryComputing Device AccessoryComputing Device Accessory
PDU TypePDU TypePDU Type Auto-Transfer Switch, MonitoredAuto-Transfer Switch, MonitoredAuto-Transfer Switch, Monitored
Input VoltageInput VoltageInput Voltage 200–240V Single-Phase200–240V Single-Phase200–240V Single-Phase
Maximum Input CurrentMaximum Input CurrentMaximum Input Current 20A (de-rated to 16A continuous in North America)20A (de-rated to 16A continuous in North America)20A (de-rated to 16A continuous in North America)
Input ConnectionsInput ConnectionsInput Connections Dual IEC-320 C20 Inlets (Primary + Secondary)Dual IEC-320 C20 Inlets (Primary + Secondary)Dual IEC-320 C20 Inlets (Primary + Secondary)
Output CapacityOutput CapacityOutput Capacity 3.84kW @ 240V / 16A total capacity3.84kW @ 240V / 16A total capacity3.84kW @ 240V / 16A total capacity
Output ReceptaclesOutput ReceptaclesOutput Receptacles (8) C13, (2) C19 200–240V Outlets(8) C13, (2) C19 200–240V Outlets(8) C13, (2) C19 200–240V Outlets
Frequency CompatibilityFrequency CompatibilityFrequency Compatibility 50 / 60 Hz50 / 60 Hz50 / 60 Hz
ATS Switchover TimeATS Switchover TimeATS Switchover Time 2–7 milliseconds2–7 milliseconds2–7 milliseconds
Input Cord LengthInput Cord LengthInput Cord Length 12 ft (3.66 m) – Set of two cords12 ft (3.66 m) – Set of two cords12 ft (3.66 m) – Set of two cords
Network InterfaceNetwork InterfaceNetwork Interface Pre-installed WEBCARDLX (HTML5, SNMP, Telnet, SSH)Pre-installed WEBCARDLX (HTML5, SNMP, Telnet, SSH)Pre-installed WEBCARDLX (HTML5, SNMP, Telnet, SSH)
Management SoftwareManagement SoftwareManagement Software PowerAlert Device Manager (PADM20)PowerAlert Device Manager (PADM20)PowerAlert Device Manager (PADM20)
Communications CableCommunications CableCommunications Cable Micro-USB to USB-A configuration/console cableMicro-USB to USB-A configuration/console cableMicro-USB to USB-A configuration/console cable
MountingMountingMounting 1U Horizontal Rackmount (19-inch EIA-standard rack)1U Horizontal Rackmount (19-inch EIA-standard rack)1U Horizontal Rackmount (19-inch EIA-standard rack)
Minimum Rack DepthMinimum Rack DepthMinimum Rack Depth 46.48 cm (18.3 in)46.48 cm (18.3 in)46.48 cm (18.3 in)
DimensionsDimensionsDimensions 44 x 439 x 376 mm (1.72 x 17.33 x 14.77 in)44 x 439 x 376 mm (1.72 x 17.33 x 14.77 in)44 x 439 x 376 mm (1.72 x 17.33 x 14.77 in)
WeightWeightWeight 4.67 kg (10.30 lbs)4.67 kg (10.30 lbs)4.67 kg (10.30 lbs)
Operating TemperatureOperating TemperatureOperating Temperature 0° to 40°C (32° to 104°F)0° to 40°C (32° to 104°F)0° to 40°C (32° to 104°F)
Storage TemperatureStorage TemperatureStorage Temperature -30° to 50°C (-22° to 122°F)-30° to 50°C (-22° to 122°F)-30° to 50°C (-22° to 122°F)
Relative HumidityRelative HumidityRelative Humidity 5% to 95% non-condensing5% to 95% non-condensing5% to 95% non-condensing
Operating ElevationOperating ElevationOperating Elevation 0–3000 m (0–10,000 ft)0–3000 m (0–10,000 ft)0–3000 m (0–10,000 ft)
ComplianceComplianceCompliance UL 62368-1, CE, RoHS, FCC Part 15 Class A, UKCA, TAAUL 62368-1, CE, RoHS, FCC Part 15 Class A, UKCA, TAAUL 62368-1, CE, RoHS, FCC Part 15 Class A, UKCA, TAA
WarrantyWarrantyWarranty 2-Year Limited Warranty2-Year Limited Warranty2-Year Limited Warranty

Thông số tham khảo từ tài liệu công khai, có thể khác theo phiên bản. Dùng để đối chiếu khi thiết kế giải pháp.Specifications drawn from public documentation; they may vary by version. Use them to compare options while designing a solution.参数来自公开资料,可能因版本而异。用于设计方案时对照。